ECO MULTI
Air Conditioners
Ecology Newly developed power control refrigerant circuit operates without an inverter control, thus decreasing electromagnetic disturbance (harmonic current emissions) and complying with EMC standards. Economy Power control circuit and newly designed structural parts contribute to a major reduction in initial and running costs, and the required amount of refrigerant (approx. 10% ERR increase and 15% reduction of R22, when compared to the current FIT Multi System).
|
For large houses. restaurants and commercial use.
New Single ECO MULTI is sure to meet your air conditioning requirements not only for commercial use but also for residential use. |
Outdoor unit SPW-C483GYH8 SPW-C483GY8
ECO MULTI outdoor unit
Model No. |
Capacity kW
|
Number of connectable indoor units
|
Cooling |
Heating |
SPW-C483GYH8 |
14.0
|
16.0
|
6 (max.)
|
SPW-C483GY8 |
14.0
|
-
|
Operating Capacity
|
25%
|
50%
|
75%
|
100%
|
PC Compressor |
100% Operation |
OFF
|
OFF
|
ON
|
ON
|
50% Operation |
ON
|
ON
|
OFF
|
OFF
|
External Save Valve |
ON
|
OFF
|
ON
|
OFF
|
Newly developed power control compressor enables independent control of units in the air conditioning system with less cost. |
|
For large stores and buildings. With the ECO MULTI it is possible to connect indoor units with a capacity of up to 130% of the outdoor unit capacity. Assuming that the minimum capacity of an indoor unit is 2.8 kW, it is possible to connect 10 or 13 units respectively to the 22.4 kW unit, or the 28.0 kW unit. |
Outdoor unit SPW-C903GYH8 SPW-C903GY8
ECO MULTI outdoor unit
Model No. |
Capacity kW
|
Number of connectable indoor units |
Cooling |
Heating |
SPW-C703GYH8
|
22.4
|
25.0
|
10 (max.)
|
SPW-C703GY8 |
22.4
|
-
|
SPW-C903GYH8 |
28.0
|
31.5
|
13 (max.)
|
SPW-C903GY8 |
28.0
|
-
|
Twin-compressor structure featuring a power control compressor and standard compressor. The combination with an external save valve makes it possible to realize compressor capacity control for every 2.8kW. In addition, an electronic refrigerant control valve on the indoor unit realizes even more precise control of refrigerant flow volume for better capacity control in accordance with load. |
Operating Capacity |
12.5% |
25% |
37.5% |
50% |
62.5% |
75% |
87.5% |
100% |
Power Control Compressor |
100% Operation |
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
50% Operation |
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
Standard Compressor |
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
ON
|
External Save Valve |
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
|
|